UPS Solutions

One premium product page bringing together UPS Generator diesel sets, gas gensets, mobile power, clean energy, lighting towers and technical catalogue data in one organized corporate experience.

Product Index

DIESEL GENERATOR SETS

Powered by Perkins

Perkins-powered UPS diesel generator sets for commercial, industrial and mission-critical applications.

  • 50Hz and 60Hz specification ranges
  • Open type and soundproof canopy options
  • Prime and standby power solutions
  • Engineered for GCC operating conditions

Product Images

TECHNICAL DATA

TECHNICAL DATA

Diesel Generator Sets Powered by Perkins

Perkins 50Hz / 60Hz generator specifications based on catalogue pages 4–5.

Freq.ModelEngineCyl.AlternatorPrime kVAPrime kWStandby kVAStandby kWFuel PrimeFuel StandbyClosed DimensionOpen DimensionClosed WeightOpen Weight
50HzUPSP10403A-11G13TAL040 B9.07.29.97.93.03.61780*900*13801350*530*1092500400
50HzUPSP15403A-15G23TAL040 D15.012.017.013.05.06.01780*900*13801320*530*1105600450
50HzUPSP20404A-22G14TAL040 F20.316.222.317.85.36.11780*900*13801351*530*1152700450
50HzUPSP301103A-33G3TAL042 C30.024.033.026.47.28.12200*1000*15201650*770*1252850700
50HzUPSP451103A-33TG13TAL042 F45.036.049.639.710.811.72200*1000*15201650*770*1252900700
50HzUPSP601103A-33TG23TAL042 H60.048.066.052.814.615.92200*1000*15201702*801*11971000800
50HzUPSP801104A-44TG24TAL044 B80.064.088.070.418.720.52400*1100*16502050*860*131013001000
50HzUPSP1001104C-44TAG24TAL044 D101.481.4111.989.622.624.92400*1100*16502050*860*131014001050
50HzUPSP1351106A-70TG16TAL044 H135.0108.0150.0120.030.233.82850*1100*16502440*860*135916001200
50HzUPSP1501106A-70TAG26TAL044 J150.0120.0165.0132.033.436.12850*1100*16502440*860*135917001400
50HzUPSP1801106A-70TAG36TAL044 L180.0144.0200.0160.041.445.13320*1100*18502350*900*148920001600
50HzUPSP2001106A-70TAG46TAL044 M200.0160.0220.0176.045.849.43320*1100*18502350*900*148925002000
50HzUPSP2301206A-E70TTAG26TAL046 C225.0180.0250.0200.051.056.63470*1300*20202750*1000*154925002000
50HzUPSP2501506A-E88TAG36TAL046 D250.0200.0275.0220.056.964.53470*1300*20202750*1000*155030002500
50HzUPSP3001506A-E88TAG56TAL046 F300.0240.0330.0264.064.973.13770*1300*20203200*1150*198835002800
50HzUPSP4002206A-E13TAG36TAL0473 A400.0320.0450.0360.081.090.03860*1380*24203360*1120*224840003400
50HzUPSP5002506A-E15TAG26TAL0473 C500.0400.0550.0440.0100.0111.04440*1380*24203600*1150*199045004000
50HzUPSP6502806A-E18TAG26TAL0473 F650.0520.0700.0560.0132.0143.04640*1680*24204640*1680*200050004500
50HzUPSP7504006-23TAG2A6TAL049 B750.0600.0825.0660.0157.0173.05800*2240*24004200*1720*225080007000
50HzUPSP10004008TAG2A8TAL049 E1022.0818.01125.0900.0215.0240.06008*2430*25984550*2070*2391110009000
50HzUPSP12504012-46TWG2A12LSA50.2 M61250.01000.01385.01108.0259.0288.012192*2440*29004550*2070*23911300011000
50HzUPSP15004012-46TAG2A12LSA50.2 L81505.01204.01656.01325.0310.0341.012192*2440*29004600*1998*25251600013500
50HzUPSP18504016TAG1A16LSA52.3 S51844.01476.02028.01622.0383.0424.011500*3100*36005800*2740*33701700014500
50HzUPSP20004016-TAG2A16LSA52.3 S62058.01646.02263.01811.0434.0483.0-TO BE UPDATED--
50HzUPSP22504016-61TRG316LSA52.3 L92250.01800.02500.02000.0470.0529.0-TO BE UPDATED--
60HzUPSP351103A-33G3TAL042 C352838318.69.52200*1000*15201650*770*1252850700
60HzUPSP531103A-33TG13TAL042 F5343594712.914.32200*1000*15201650*770*1252900700
60HzUPSP681103A-33TG23TAL042 H6855756016.618.22200*1000*15201702*801*11971000800
60HzUPSP911104A-44TG24TAL044 B91.373100.380.322.324.42400*1100*16502050*860*131013001000
60HzUPSP1141104C-44TAG24TAL044 D1149212710122.324.42400*1100*16502050*860*131014001050
60HzUPSP1521106A-70TG16TAL044 H15212216913526.929.72850*1100*16502440*860*135916001200
60HzUPSP1691106A-70TAG26TAL044 J16913518815033.436.12850*1100*16502440*860*135917001400
60HzUPSP1971106A-70TAG36TAL044 L19715821917546.450.53320*1100*18502350*900*148920001600
60HzUPSP2251206A-E70TTAG26TAL046 C22518025020054.561.13470*1300*20202750*1000*154925002000
60HzUPSP2451506A-E88TAG26TAL046 C24519626921554.259.53470*1300*20192750*1000*154925002000
60HzUPSP2921506A-E88TAG36TAL046 D29223431725463.169.83470*1300*20202750*1000*155030002500
60HzUPSP3501506A-E88TAG56TAL046 F35228238630977.185.73770*1300*20203200*1150*198835002800
60HzUPSP4002206A-E13TAG26TAL046 H40032043835081.087.03860*1380*24193360*1120*224740003200
60HzUPSP5002506A-E15TAG16TAL0473 B500400563450102.0116.04440*1380*24193600*1150*198945004000
60HzUPSP6252806A-E18TAG1A6TAL0473 E625500687550127.0141.04640*1680*24203500*1480*209750004500
60HzUPSP7504006-23TAG2A6TAL049 B750600825660177.0199.05800*2240*24004200*1720*225080007000
60HzUPSP8444006-23TAG3A6TAL049 C844675938750200.0224.05800*2240*24004175*1720*221885007500
60HzUPSP9954008TAG2A8TAL049 E9957961097878224.0249.06008*2430*25984550*2070*2391110009000
60HzUPSP12504012-46TWG2A12LSA50.2 M61253100213851108266.0298.012192*2440*29004550*2070*23911300011000
60HzUPSP15004012-46TAG2A12LSA50.2 L81511120816611329319.0251.012192*2440*29004600*1998*25251600013500
Need More Technical Information?

Download the Complete UPS E-Catalogue

Explore the full range of diesel generators, gas generators and lighting towers with complete technical specifications.

Download PDF
DIESEL GENERATOR SETS

Powered by Cummins

Cummins-powered generator sets built for durability, serviceability and high-load operation.

  • 50Hz and 60Hz power range
  • Open and enclosed gensets
  • Heavy-duty industrial applications
  • OEM-backed component ecosystem

Product Images

TECHNICAL DATA

TECHNICAL DATA

Diesel Generator Sets Powered by Cummins

Cummins 50Hz / 60Hz generator specifications based on catalogue pages 6–7.

Freq.ModelEngineCyl.AlternatorPrime kVAPrime kWStandby kVAStandby kWFuel Cons. L/HrClosed DimensionClosed WeightOpen Weight
50HzUPSC354BT3.9-G24LSA/TAL042 D35.028.038.530.86.71700*900*1357400360
50HzUPSC404BT3.9-G24LSA/TAL042 E40.032.044.035.28.01700*900*1357500450
50HzUPSC604BTA3.9-G24LSA/TAL042 H60.048.066.052.811.01700*900*1357600540
50HzUPSC1006BT5.9-G16LSA/TAL044 D100.080.0110.088.016.01700*900*1357600540
50HzUPSC1146BT5.9-G16LSA/TAL044 D114.091.2125.4100.322.02100*950*1180850765
50HzUPSC1306BTAA5.9-G26LSA/TAL044 H130.0104.0143.0114.426.02100*950*1180950855
50HzUPSC1606CTA8.3-G26LSA/TAL044 J160.0128.0176.0140.833.02100*950*11801050945
50HzUPSC2006CTAA8.3-G16LSA/TAL046 B200.0160.0220.0176.043.02800*1100*16371100990
50HzUPSC2506CTAA8.3-G26LSA/TAL046 D250.0200.0275.0220.044.02800*1100*163712501125
50HzUPSC300NT855-G16LSA/TAL046 F300.0240.0330.0264.061.02800*1100*163715001350
50HzUPSC350NTA855-G1A6LSA/TAL046 H350.0280.0385.0308.072.02800*1100*163716001440
50HzUPSC410KTA19-G26LSA/TAL047 A410.0328.0451.0360.8108.02800*1100*163720151813.5
50HzUPSC450KTA19-G36LSA/TAL047 B450.0360.0495.0396.097.03470*1300*160025002250
50HzUPSC500KTA19-G46LSA/TAL047 C500.0400.0550.0440.0100.03470*1300*160024002160
50HzUPSC568KTAA19-G76LSA/TAL047 D568.0454.4624.8499.8113.03470*1300*160025502295
50HzUPSC750KTA38-G212LSA 49.1 M6750.0600.0825.0660.0157.03470*1300*160027502475
50HzUPSC909KTA38-G2A12LSA 49.1 L10909.0727.2999.9799.9191.03860*1380*180030302727
50HzUPSC1000KTA38-G512LSA/TAL049 E1000.0800.01100.0880.0190.03860*1380*180033162984.4
50HzUPSC1125KTA50-G312LSA 50.2 M61125.0900.01237.5990.0252.04440*1380*240034533107.7
60HzUPSC354BT3.9-G24LSA/TAL042 D35.028.038.530.86.71700*900*1357400360
60HzUPSC404BT3.9-G24LSA/TAL042 E40.032.044.035.28.01700*900*1357500450
60HzUPSC604BTA3.9-G24LSA/TAL042 H60.048.066.052.811.01700*900*1357600540
60HzUPSC1006BT5.9-G16LSA/TAL044 D100.080.0110.088.016.01700*900*1357600540
60HzUPSC1146BT5.9-G16LSA/TAL044 D114.091.2125.4100.322.02100*950*1180850765
60HzUPSC1306BTAA5.9-G26LSA/TAL044 H130.0104.0143.0114.426.02100*950*1180950855
60HzUPSC1606CTA8.3-G26LSA/TAL044 J160.0128.0176.0140.833.02100*950*11801050945
60HzUPSC2006CTAA8.3-G16LSA/TAL046 B200.0160.0220.0176.043.02800*1100*16371100990
60HzUPSC2506CTAA8.3-G26LSA/TAL046 D250.0200.0275.0220.044.02800*1100*163712501125
60HzUPSC300NT855-G16LSA/TAL046 F300.0240.0330.0264.061.02800*1100*163715001350
60HzUPSC350NTA855-G1A6LSA/TAL046 H350.0280.0385.0308.072.02800*1100*163716001440
60HzUPSC410KTA19-G26LSA/TAL047 A410.0328.0451.0360.8108.02800*1100*163720151813.5
60HzUPSC450KTA19-G36LSA/TAL047 B450.0360.0495.0396.097.03470*1300*160025002250
60HzUPSC500KTA19-G46LSA/TAL047 C500.0400.0550.0440.0100.03470*1300*160024002160
60HzUPSC568KTAA19-G76LSA/TAL047 D568.0454.4624.8499.8113.03470*1300*160025502295
60HzUPSC750KTA38-G212LSA 49.1 M6750.0600.0825.0660.0157.03470*1300*160027502475
60HzUPSC909KTA38-G2A12LSA 49.1 L10909.0727.2999.9799.9191.03860*1380*180030302727
60HzUPSC1000KTA38-G512LSA/TAL049 E1000.0800.01100.0880.0190.03860*1380*180033162984.4
60HzUPSC1125KTA50-G312LSA 50.2 M61125.0900.01237.5990.0252.04440*1380*240034533107.7
Need More Technical Information?

Download the Complete UPS E-Catalogue

Explore the full range of diesel generators, gas generators and lighting towers with complete technical specifications.

Download PDF
DIESEL GENERATOR SETS

Powered by Lister Petter

Water-cooled Lister Petter generating sets with compact industrial configurations.

  • Water-cooled diesel engine
  • AVR voltage regulation
  • Open or acoustic canopy options
  • Starter battery and control panel options

Product Images

TECHNICAL DATA

TECHNICAL DATA

Diesel Generator Sets Powered by Lister Petter

Lister Petter Prime and Standby Power Ratings based on catalogue page 9.

ModelKVAKWDimension L×W×HWeight KGEngine ModelCyl.Capacity L/CBore mmStroke mmFuel Cons. L/Hr
StandbyContinuousStandbyContinuous
L. 1011108.881300×500×800410LPW 220.9386802
L. 15171513.6121300×500×800450LPW 331.3986803
L. 20222017.6161400×620×900490LPW 441.8686804
L. 25282522.4201400×620×900520LPW 4T41.9686805
L. 30333026.4241600×720×1000590DWS 443.3386807
L. 1301121029081.62400×750×1300960LLO 12569.72116.6135.925
L. 140150136120108.82800×800×14501150LLO 15069.72116.6135.935
L. 2001661501321202800×800×14501250LLO 20069.72116.6135.942
L. 2302292081831662900×1000×17002000LLO 23069.72116.6135.948
L. 2502502282001822900×1000×17002100LLO 25069.72116.6135.952
Need More Technical Information?

Download the Complete UPS E-Catalogue

Explore the full range of diesel generators, gas generators and lighting towers with complete technical specifications.

Download PDF

Standard Features

Starting system12V starter battery and leads
ProtectionCircuit breaker with thermal overload
DocumentationElectrical diagram and operator handbook
OptionsResidential silencer and acoustic canopy kit
DIESEL GENERATOR SETS

Powered by Hyundai (Doosan)

Doosan diesel generator sets for compact-to-heavy applications with strong output range.

  • 50Hz specification range
  • Industrial engine platforms
  • Prime and standby duties
  • Suitable for packaged generator assemblies

Product Images

TECHNICAL DATA

TECHNICAL DATA

Diesel Generator Sets Powered by Hyundai (Doosan)

Doosan Specification 50Hz.

Genset TypeEngineNo. of CylindersAlternatorPrimeStandbyCons. L/HDimension MWeight KG
KVAKWKVAKWLWH
UPSD165DP086TA6LSA/TAL044 J16513218418433.72.50.761.41700
UPSD180P086TI-16LSA/TAL044 L18014419915935.43.321.11.852000
UPSD215P086TI6LSA/TAL044 M21517224319443.12.70.991.722500
UPSD245DP086LA6LSA/TAL046 D24519627421948.73.421.12.012800
UPSD300P126TI6LSA/TAL046 F29323433126558.13.41.121.853200
UPSD323P126TI-116LSA/TAL046 F32325835928763.13.861.382.423400
UPSD350DP126LA6LSA/TAL046 H34627738130568.13.861.382.423600
UPSD389DP126LB6LSA/TAL046 H38931143334676.13.861.382.423800
UPSD434P158LE8LSA/TAL047343434749839889.33.861.382.423900
UPSD490DP158LC8LSA/TAL047349039254143399.64.441.382.484100
UPSD560DP158LD8LSA/TAL0473560448618494115.14.441.382.484500
UPSD608DP180LA10LSA/TAL0473608486670536123.64.441.382.484800
UPSD675DP180LB10LSA/TAL0473675540745596136.44.641.682.425000
UPSD725DP222LB12LSA/TAL049 B725580800640147.15.82.586200
Need More Technical Information?

Download the Complete UPS E-Catalogue

Explore the full range of diesel generators, gas generators and lighting towers with complete technical specifications.

Download PDF
GAS GENARATOR SOLUTIONS

PERKINS GAS GENERATOR SETS

Ultimate Power Solution supplies high-performance gas generator sets powered by Perkins spark-ignited gas engines, engineered for continuous and standby power applications. Perkins gas engines are renowned for their reliability, fuel efficiency, low operating costs, and long service life, making them an ideal solution for industrial, commercial, utility, and CHP (Combined Heat & Power) installations.

Available Engine Series

* Perkins 4000 Series Gas Engines (4006, 4008, 4012 & 4016 TESI)

Compatible Fuels

* Natural Gas (NG)

* Pipeline Gas* Biogas (subject to gas quality)

* Landfill Gas (with suitable gas treatment)

* Coal Mine Methane (application dependent)  

Waukesha Gas Generator Sets

Ultimate Power Solution also supplies premium gas-powered generator sets equipped with Waukesha® gas engines, recognized worldwide for exceptional durability, high efficiency, and outstanding performance in demanding continuous-duty applications. Waukesha engines are widely used in power generation, oil & gas, industrial facilities, utilities, and CHP projects where maximum reliability is essential.

Available Engine Series

* Waukesha VHP Series

* Waukesha VGF Series

* Waukesha 275GL+ Series

Compatible Fuels

* Natural Gas

* Associated Gas

* Wellhead Gas

* Biogas

* Landfill Gas

* Digester Gas

* Other low-BTU gaseous fuels (depending on composition and application)  

Why Choose Ultimate Power Solution?

* Prime & Standby Power Solutions

* Customized Power Ratings

* Industrial & Commercial Applications

* Low Emissions & High Fuel Efficiency

* Automatic Synchronization & Load Sharing

* Sound-Attenuated or Containerized Packages

* Complete Installation, Commissioning & After-Sales Support

Product Images

MARINE AUXILIARY GEN-SETS

Marine Auxiliary

Marine auxiliary generator sets prepared for offshore, vessel and marine support power requirements.

  • Marine auxiliary power packages
  • Onan / marine generator options
  • Robust enclosed configurations
  • Built for demanding environments

Product Images

TECHNICAL DATA

Marine Auxiliary Data

ApplicationVessels, auxiliary systems and marine support
ConfigurationOpen or enclosed marine generator packages
SupportSpare parts and after-market service
WarrantyInternational warranty support where applicable
MOBILE GEN-SETS

Mobile Power

Trailer and vehicle power stations for fast deployment, rental projects and field operations.

  • Vehicle power station options
  • Trailer-mounted generator sets
  • Fast site deployment
  • Suitable for temporary and emergency power

Product Images

TECHNICAL DATA

Mobile Gen-Set Data

FormatsVehicle power station / trailer power station
MobilityTowable and field-ready solutions
Use casesRental, construction, emergency and remote sites
SupportInstallation, operation and field service
HEAVY FUEL POWER STATIONS

Heavy Fuel

Heavy fuel power stations for large-scale generation, continuous duty and industrial infrastructure.

  • Large power station configuration
  • Industrial engine platforms
  • Fuel systems and site infrastructure
  • Designed for high-output operations

Product Images

TECHNICAL DATA

Heavy Fuel Power Station Data

ApplicationIndustrial power generation and power stations
ScopeEngine, alternator, fuel and cooling systems
OperationContinuous and standby power capability
IntegrationDesigned around site-specific requirements
WIND TURBINE

Clean Energy

Wind turbine and wind farm solutions for clean-energy generation and hybrid power projects.

  • Wind turbine integration
  • Clean energy applications
  • Hybrid solar and wind solutions
  • Project-based engineering support

Product Images

TECHNICAL DATA

Wind Turbine Data

ApplicationWind turbine and wind farm projects
IntegrationHybrid clean energy power solutions
SupportEngineering-led project configuration
Related scopeSolar and wind generator systems
HYDRO GENERATORS

Clean Energy

Hydro generator solutions for water-driven power projects and renewable energy applications.

  • Hydro generator assemblies
  • Renewable energy applications
  • Project-based equipment supply
  • Suitable for clean energy infrastructure

Product Images

TECHNICAL DATA

Hydro Generator Data

ApplicationHydro power generation
ScopeTurbine generator equipment and project support
Power typeRenewable / clean energy
EngineeringConfigured around site conditions
SOLAR POWER STATION

Clean Energy

Solar power stations and combined solar/wind generator solutions for clean power applications.

  • Solar power station projects
  • Solar + wind generator solutions
  • Clean power provider capability
  • Hybrid project applications

Product Images

TECHNICAL DATA

Solar Power Station Data

ApplicationSolar power station and clean energy projects
IntegrationSolar, wind and hybrid power systems
Project examplesSolar fields, rooftop and industrial installations
SupportEngineering, supply and system integration
TOWER LIGHT – PERKINS

Lighting Tower

Perkins-powered lighting tower solutions for industrial, site and rental operations.

  • Manual operation options
  • 4 × 1000W metal halide lights
  • Water-cooled diesel engine
  • Towable site lighting solution

Product Images

TECHNICAL DATA

TECHNICAL DATA

Lighting Tower Technical Data – Perkins

UPS Mobile Lighting Tower Specification.

SpecificationUPS-MLT15UPS-MLT20
Product ModelUPS-MLT15UPS-MLT20
Length (mm)2430 (1530 - Dismantle the tow bar)
Width (mm)1302
Height (mm)2597
Weight (Kg) (NET)1150
Engine BrandPERKINS
Engine Model403A-15G1404A-22G1
Frequency (Hz)5050
Speed (rpm)15001500
Prime Power / Standby Power (kVA)13 / 1520.3 / 22.3
Number of Cylinder4
Diesel Engine CharactersWater cooled diesel engine
Cylinder Bore (mm)84 × 90
Combustion SystemIndirect Injection
Compression Ratio22.5 : 123.3 : 1
Alternator BrandLeroy Somer / Meccalte / UPS / Stamford
Insulation / Alternator TypeClass H / Brushless
Rating380 / 220
Fuel Consumption (Prime Power)3.7 L/hr5.3 L/hr
Type of LightsMetal Halide Floodlights
Number & Power of Lights4 × 1000W
Mast Lifting & ExtensionManual Operation
Mast Rotation390° Manual Operation
Light Up/Down TurningManual Operation
Base SupportManual Operation
Trailer Suspension SystemTorsion Axle (AL-KO)
Braking SystemInertia drum brake with stable towing height, Parking brake
HitchDraw eye / Towing Hook
Tire and Rim Size185 / 14"
Acoustic Pressure65 dB(A) @ 7 meters away
Need More Technical Information?

Download the Complete UPS E-Catalogue

Explore the full range of diesel generators, gas generators and lighting towers with complete technical specifications.

Download PDF
TOWER LIGHT – LISTER PETTER

Lighting Tower

Lister Petter-powered lighting tower systems for job sites, rental fleets and emergency lighting.

  • Lister Petter diesel engine
  • Manual / hydraulic mast options
  • Metal halide floodlights
  • Stable towable chassis

Product Images

TECHNICAL DATA

TECHNICAL DATA

Lighting Tower Technical Data – Lister Petter

UPS Mobile Lighting Tower – Lister Petter Specification.

Specification50Hz60Hz
Product ModelUPS-MLT8
Length (mm)2784 (2260 - Dismantle the tow bar)
Width (mm)1360
Height (mm)2170
Mast Height (Fully extended)9m
Weight (Kg)(NET)1150
Engine BrandLISTER PETTER
Engine ModelD1105
Frequency (Hz)5060
Speed (rpm)15001800
Continued Power (kVA)7979
Number of Cylinder3
Diesel Engine CharactersWater cooled diesel engine
Combustion TypePrecombustionIndirect Injection
Engine AspirationNatural
Emission LevelStage 3Tier 4Stage 3Tier 4
Alternator BrandMeccalte
Alternator ModelLT 130
Frequency (Hz)50605060
Continued Power (kVA)67.567.5
AlternatorBrushless and Single Phase
Rating (V)230
Alternator InsulationH
Fuel Tank Capacity135 Liters (35US Gallons)
Fuel Tank Operating Hours65 Hours
Type of LightsMetal Halide Floodlights
Number & Power of Lights4 × 1000W
Mast Lifting & ExtensionHydraulic Operation
Mast Rotation359 degrees Manual Operation
Light up/down turningManual Operation
Base SupportManual Operation
Trailer Suspension SystemTorsion Axle ( AL - KO)
Braking SystemInertia drum braking with stable towing height, parking brake
HitchDraw Eye / Towing Hook
Tire & Rim Size185 / 14"
Acoustic Pressure65dB (A) @ 7 meters away
Load Capacity for 40' GP(Units)8
Need More Technical Information?

Download the Complete UPS E-Catalogue

Explore the full range of diesel generators, gas generators and lighting towers with complete technical specifications.

Download PDF
TOWER LIGHT – KUBOTA

Lighting Tower

Kubota-powered mobile lighting tower for reliable site lighting and compact deployment.

  • Kubota diesel engine options
  • Mobile lighting technical data
  • 4 × 1000W light output
  • Designed for site and rental operations

Product Images

TECHNICAL DATA

TECHNICAL DATA

Mobile Lighting Tower Technical Data – Kubota

UPS Mobile Lighting Tower – Kubota Specification.

Specification50Hz60Hz
Product ModelUPS-MLT5
Length (mm)2430 (1530 - Dismantle the tow bar)
Width (mm)1302
Height (mm)2597
Weight (Kg)(NET)1150
Engine BrandKUBOTA
Engine ModelZ482-BG
Frequency (Hz)5060
Speed (rpm)15001800
Continued Power (kW)56.9
Standby Power (kW)6.217.5
Number of Cylinder2
TypeVertical, Water-cooled, 4 Cycle Diesel Engine
Governor RegulationLess than 5%
GovernorMechanical
Fuel Injection Pump TypeDirect
Compression Ratio23.5:1
Lubricating Oil Capacity2.5 (0.66US GAL)
Alternator BrandLinz
Insulation / Alternator TypeClass H / Brushless
Rating (V)380/220
Type of LightsMetal Halide / Led Floodlights
Number and Power of Lights4 × 1000W
Mast Lifting & ExtensionManual Operation
Mast Rotation390 Manual Operation
Light up/down TurningManual Operation
Base SupportManual Operation
Trailer Suspension SystemTorsion Axle (AL-KO)
Braking SystemInertia drum brake with stable towing height, Parking brake
HitchDraw eye / Towing Hook
Tire and Rim Size185/14"
Acoustic Pressure65 dB (A) @ 7 meters away
Need More Technical Information?

Download the Complete UPS E-Catalogue

Explore the full range of diesel generators, gas generators and lighting towers with complete technical specifications.

Download PDF

Need a custom power solution for your next project?

From requirement to reliable operation, UPS Generator provides engineered power solutions for industrial projects,
contractors, consultants and facility operators.